, , ,

HYDAC Standard Accumulator Charging Kit (FPU-1-250 F 2.5 G2 A3/H)

0 out of 5

The HYDAC charging and testing unit FPU is used to charge accumulators with nitrogen or to check or to change the existing pre-charge pressure in accumulators. For this purpose the charging and testing unit is screwed onto the gas valve of the hydraulic accumulator and connected via a flexible charging hose to a commercial nitrogen bottle. If the nitrogen pressure is only to be checked or reduced, the charging hose does not need to be connected. The unit has a screw-type fitting with a built-in pressure gauge, check valve and a spindle for opening the accumulator gas valve to check the pressure.

Read more
, ,

HYDAC Standard Accumulator Charging Kit (FPU-2-800 / 1000 F 2.5 G2 A1 K)

0 out of 5

The HYDAC charging and testing unit FPU is used to charge accumulators with nitrogen or to check or to change the existing pre-charge pressure in accumulators. For this purpose the charging and testing unit is screwed onto the gas valve of the hydraulic accumulator and connected via a flexible charging hose to a commercial nitrogen bottle. If the nitrogen pressure is only to be checked or reduced, the charging hose does not need to be connected. The unit has a screw-type fitting with a built-in pressure gauge, check valve and a spindle for opening the accumulator gas valve to check the pressure.

Read more
, , ,

HYDAC STANDARD ACCUMULATOR SAFETY BLOCK (SAF 10 M 1 2 Y 1 T 210 A - S13 – LPI – A9)

0 out of 5

The HYDAC safety and shut-off block is a hydraulics accessories element for protection from excess pressure on the fluid side and for the shut-off and relief of hydraulic accumulators. It takes into account the applicable safety regulations according to DIN EN ISO 4413 and the German Industrial Safety Regulation (BetrSichV). The HYDAC pressure relief valve (DB12) is used in the SAF series. It is a directacting pressure relief valve in poppet valve construction with excellent opening and closing characteristics. This version of the DB12 complies with the requirements of the European Pressure Equipment Directive (PED) with CE marking and is supplied with a declaration of conformity and operating instructions.

Read more
, ,

HYDAC STANDARD ACCUMULATOR SAFETY BLOCK (SAF 20 M 1 2 Y 1 T 210 A - S13 – LPI – A9)

0 out of 5

The HYDAC safety and shut-off block is a hydraulics accessories element for protection from excess pressure on the fluid side and for the shut-off and relief of hydraulic accumulators. It takes into account the applicable safety regulations according to DIN EN ISO 4413 and the German Industrial Safety Regulation (BetrSichV). The HYDAC pressure relief valve (DB12) is used in the SAF series. It is a directacting pressure relief valve in poppet valve construction with excellent opening and closing characteristics. This version of the DB12 complies with the requirements of the European Pressure Equipment Directive (PED) with CE marking and is supplied with a declaration of conformity and operating instructions.

Read more
, ,

HYDAC STANDARD ACCUMULATOR SAFETY BLOCK (SAF 20 M 1 2 Y 1 T 210 A - S13 – LPI – A9) (Copy)

0 out of 5

The HYDAC safety and shut-off block is a hydraulics accessories element for protection from excess pressure on the fluid side and for the shut-off and relief of hydraulic accumulators. It takes into account the applicable safety regulations according to DIN EN ISO 4413 and the German Industrial Safety Regulation (BetrSichV). The HYDAC pressure relief valve (DB12) is used in the SAF series. It is a directacting pressure relief valve in poppet valve construction with excellent opening and closing characteristics. This version of the DB12 complies with the requirements of the European Pressure Equipment Directive (PED) with CE marking and is supplied with a declaration of conformity and operating instructions.

Read more
, ,

HYDAC STANDARD ACCUMULATOR SAFETY BLOCK (SAF 32 M 1 2 Y 1 T 210 A - S13 – LPI – A9)

0 out of 5

The HYDAC safety and shut-off block is a hydraulics accessories element for protection from excess pressure on the fluid side and for the shut-off and relief of hydraulic accumulators. It takes into account the applicable safety regulations according to DIN EN ISO 4413 and the German Industrial Safety Regulation (BetrSichV). The HYDAC pressure relief valve (DB12) is used in the SAF series. It is a directacting pressure relief valve in poppet valve construction with excellent opening and closing characteristics. This version of the DB12 complies with the requirements of the European Pressure Equipment Directive (PED) with CE marking and is supplied with a declaration of conformity and operating instructions.

Read more
, ,

HYDAC STANDARD ACCUMULATOR SAFETY BLOCK (SAF 8 M 1 2 Y 1 T 210 A - S13 – LPI – A9)

0 out of 5

The HYDAC safety and shut-off block is a hydraulics accessories element for protection from excess pressure on the fluid side and for the shut-off and relief of hydraulic accumulators. It takes into account the applicable safety regulations according to DIN EN ISO 4413 and the German Industrial Safety Regulation (BetrSichV). The HYDAC pressure relief valve (DB12) is used in the SAF series. It is a directacting pressure relief valve in poppet valve construction with excellent opening and closing characteristics. This version of the DB12 complies with the requirements of the European Pressure Equipment Directive (PED) with CE marking and is supplied with a declaration of conformity and operating instructions.

Read more
, ,

HYDAC Standard Bladder Accumulator (SB 330-1 A 1/112 U-330 A 050 )

0 out of 5

A bladder accumulator consists of a fluid section and a gas section with the bladder acting as the gas-proof separation element. The fluid around the bladder is connected to the hydraulic circuit so that the bladder accumulator draws in fluid when the pressure increases and the gas is compressed. When the pressure drops, the compressed gas expands and forces the stored fluid into the circuit.

Original price was: 5,552.64 ر.س.Current price is: 4,435.20 ر.س.
Add to cart
, , ,

HYDAC Standard Bladder Accumulator (SB 330-10- A 1/112 U-330 A 050 )

0 out of 5

A bladder accumulator consists of a fluid section and a gas section with the bladder acting as the gas-proof separation element. The fluid around the bladder is connected to the hydraulic circuit so that the bladder accumulator draws in fluid when the pressure increases and the gas is compressed. When the pressure drops, the compressed gas expands and forces the stored fluid into the circuit.

Original price was: 10,575.36 ر.س.Current price is: 8,455.68 ر.س.
Add to cart